Filtsel - filter select, Flow - flow control, Fmp - first mic priority mode – ClearOne XAP 800 User Manual

Page 112: Appendices ~ appendix e: serial commands, Argument details

Advertising
background image

106

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

FILTSEL - Filter Select

This command turns on and off the filters on input and audio processing channels.

Command form: DEVICE FILTSEL <Channel> <Group> <Node> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

FILTSEL

Command form

Channel

See Groups and Channels, page 97

Group

M = Mic Inputs, P = Processing Channels

Node

1-4, or * for all (selects mic input filter)

1-15, or * for all (selects processing channel filter)

Value

0 = Off, 1 = On, 2 = Toggle, Null to return current state

Example:

#54 FILTSEL B P 2 1 On XAP 800 unit 4 (#54), the filter

(FILTSEL) on processing (P) channel B, node 2, is set to on (1).

FLOW - Flow Control

This command selects/reports the flow control of the serial port on the unit.

Hardware flow control is implemented using DTR and DSR.

Command form:

DEVICE FLOW [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

FLOW

Command form

Value

0 = Off, 1 = On, 2 = Toggle, Null to return current state

Example:

#56 FLOW 1 On XAP 800 unit 6 (#56), the flow control (FLOW) to

the RS-232 port is set to on (1).

FMP - First Mic Priority Mode

This command selects/reports first Mic priority mode for a gating group.

Command form: DEVICE

FMP

<Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

FMP

Command form

Channel

1–4, A–D (selects gating group)

Value

0 = Off, 1 = On, 2 = Toggle, Null returns the current mode

Example:

#55 FMP A 1 On XAP 800 unit 5 (#55), the first mic priority mode

(FMP) for gating group A is set to on (1).