System Configuration

~ Processing

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Post Compressor Gain

Adjust the compressor gain with the gain slider or by

using the

▲ and ▼ buttons.The graph reflects the input/output decibel levels with

the gain setting you select.

Threshold

Threshold determines the RMS level at which the compressor begins to

operate. The range is from -30 to +20dBu. Default is 0dBu.

Ratio

Ratio changes the rate of compression applied to the input signal as the

signal exceeds the threshold level. The range is 1:1 to 1:20dB. Default is 1:1.

Attack

Attack determines how quickly compression is enabled. It is calibrated in

milliseconds. The range is 0 to 100ms in .5ms steps. Default is 10ms.

Release

Release determines how quickly compression is disabled. The range is

100ms to 2 seconds, in 5ms increments. Default is 500ms.

Input meter

This peak meter shows the level of the signal as it enters the

compressor.

Compression meter

This peak meter shows the instantaneous compression value

at a given time.

Filters

The Filter button on the selected Processing channel opens the Processing Filters

window. Here, you can configure all filters available in G-Ware: All Pass, Bessel,

Butterworth, CD Horn, High Pass, High Shelving, Linkwitz-Riley, Low Pass, Low

Shelving, Notch, and PEQ.

Figure 3.54. Processing Filters window