ClearOne XAP 800 User Manual

Page 16

Advertising
background image

Installation

~ Hardware Setup

10

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

To connect the unit

1.

Place the unit in a standard 19-inch rack and attach it securely.

2.

If you are using a custom controller for control and status, plug it into the

DB25 Control/Status A or B port [D].

If you are using an external RS-232 controller, connect it to the

RS-232 port [I].

3.

Wire the inputs and outputs to the XAP 800 using the provided three-

terminal Phoenix push-on connectors. These connectors are designed for easy

wiring; simply insert the desired wire into the appropriate connector opening

and tighten down the top screw.

Inputs 1–8 [B] Mic or line level inputs

Inputs 9–12 [F] Line level inputs only

Outputs 1–12 [E] Line level outputs

4.

If you are using a ClearOne Remote Panel, wire it to the RS-485 port [C]

using the provided four-terminal Phoenix push-on connectors.

5.

Plug in the XAP 800 to complete the installation. The power output [A] will

operate at any level between 100–240VAC and 50–60Hz.

If you are installing only one XAP 800 and are not connecting it to any other XAP

or PSR1212 units, you have completed the hardware installation.

Figure 2.2. XAP 800 rear-panel connectors

The three terminals in

the Phoenix connector

correspond with the rear-

panel audio contacts (from left to

right): + (positive), – (negative),

and

(ground).

✍ ✍

Figure 2.3. Phoenix push-on connector

Advertising