Macro - macro execution/reporting, Master - expansion bus master mode, Max - maximum gain setting – ClearOne XAP 800 User Manual

Page 120

Advertising
background image

MACRO - Macro Execution/Reporting

This command executes a specified macro or reports the last macro executed. There

are 255 macros that can be specified.

Command form: DEVICE MACRO [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

MACRO

Command form

Value

1-255

Value to execute user macros

Example:

#55 MACRO 1 On XAP 800 unit 5 (#55), Macro (MACRO) 1 is run.

MASTER - Expansion Bus Master Mode

This command reports the mode of the unit. The mode can be Master or Slave.

Command form: DEVICE MASTER [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

MASTER

Command form

Value

1 = Master, 2 = Slave, Null = Current mode of the unit

Example:

#56 MASTER 2 On XAP 800 unit 6 (#56), the MASTER mode is set

to slave (2)

MAX - Maximum Gain Setting

This command changes or reports back the maximum gain setting for an input,

output or assignable processing block.

Command form: DEVICE

MAX <Channel> <Group> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

MAX

Command form

Channel

See Groups and Channels, page 97

Group

I, O, M, P, L

Value

-65.00 to 20.00

dB

Null to return the current setting

Example:

#51 MAX 2 M 10 On XAP 800 unit 1 (#51), the maximum (MAX)

relative gain setting for mic (M) channel 2 is 10dB.

114

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

The response indicates

execution of the macro,

but does not indicate that

each command within the macro

was executed.

✍ ✍

This setting will affect all

relative gain adjustments.

✍ ✍