Minit - modem initialization string, Minmax - minimum and maximum gain setting, Argument details – ClearOne XAP 800 User Manual

Page 122: Appendices ~ appendix e: serial commands

Advertising
background image

MINIT - Modem Initialization String

This command sets/reports the modem initialization string of the serial port when in

modem mode.

Command form: DEVICE MINIT [String]

Argument details

Name

Description

Device

0–7 or * to select all units

MINIT

Command form

String

1-80 characters (select string characters to be sent to the modem

when the unit is initialized

CLEAR = clears the modem initialization string

Null = Current string

Example:

#56 MINIT ATZ On XAP 800 unit 6 (#56), the modem initialization

string (MINIT) is ATZ.

MINMAX - Minimum and Maximum Gain Setting

This command changes or reports back the minimum and maximum gain setting for

an input, output or assignable processing block.

Command form: DEVICE MINMAX <Channel> <Group> [Minimum] [Maximum]

Argument details

Name

Description

Device

0–7 or * to select all units

MINMAX

Command form

Channel

See Groups and Channels

Group

I, O, M, P, L

Minimum

-65.00 to 20.00, Null to return current settings

Maximum

-65.00 – 20.00

Example:

#55 MINMAX 2 M -12 10 On XAP 800 unit 5 (#55), the minimum

and maximum (MINMAX) relative gain settings for mic (M) channel 2 are -12dB

and 10dB respectively.

116

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands