Advanced Configuration

~ Presets

56

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Figure 4.3. Preset Configuration pane

Matrix Screen

The Matrix Screen in the Preset Mode is very similar to the Matrix Screen in

Configuration Mode. All Input, Output, and Processing windows can be accessed by

clicking on their respective buttons. You can also create custom labels by clicking on

the current labels.

The routing matrix is grayed out because no routing changes have been made.

When you click on the number or letter of an input, the row becomes active and

you can change the routing, gate status, and cross point attenuation. All

parameters for the selected input will be saved in the preset including routing.

Also, the parameters for any outputs with a cross point in the selected row will be

saved. Input rows that are not selected remain gray, or masked, and will not be

affected when the preset is run.

Preset Configuration pane

The Preset Configuration pane is used to create preset properties such as number,

name, and description as well as create custom preset controls, assign the preset to a

gating group, select macros, and configure virtual EC references.

Preset Selection.

Use the Preset Selection list to assign a number to the preset

you are creating or to select an existing preset for editing.

Protected.

Select the Protected check box to lock your preset. Locked presets are

indicated by a padlock icon. Presets that are locked do not require the password

to be run. However, the password is required to make changes to the preset. The

preset password is set in the Unit Properties window; see page 26.

Status Bar

Preset

Matrix Screen

G-Ware
Menus

G-Ware Toolbar

Preset
Configuration
Pane

Figure 4.2. Preset Mode