~ LCD Programming

16

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

ClearOne recommends

that you leave Flow

Control enabled.

✍ ✍

The modem initialization

string can only be set via

the MINIT serial

command (see page 116 or the

G-Ware software. It cannot be set

through the front panel LCD.

✍ ✍

You can set the modem

password using the

MPASS serial command

(see page 117) or in G-Ware (see

page 26).

✍ ✍

Flow Control (hardware)

The XAP 800 uses the RTS and CTS pins on the RS-232 port to regulate the

transmission and reception of data. You can enable or disable flow control on the

front panel of unit and select the flow control type in the Site Properties window of

G-Ware (see page 23). If you select On (default) from the front panel menu, select

Hardware as the flow control type in the Site Properties window. If you disable flow

control on the front panel, select None in the Site Properties window. When None is

selected, the XAP 800 ignores flow control, making the connected external control

device ensure that data is not lost. Software flow control (Xon/Xoff) is supported by

the XAP/PSR units and is only used with a pass-through device, such as a modem.

To avoid communication errors, ClearOne strongly recommends that you

connect all DB9 pins and enable flow control when connecting to a PC.

Enable Modem

This parameter configures the RS-232 port for connection of a modem. When On is

selected, the XAP 800 will send an initialization string to the modem on power-up

and require a password before data transfer is allowed through the port. When Off

(default) is selected, the password is disabled.

To use the XAP 800 with a modem

1.

Match the baud rate of the modem to that of the XAP 800.

2.

Turn off Serial Echo on the modem.

3.

Turn off the modem’s response mode (e.g., no OK messages, ring, etc.).

4.

Enable auto-answer on the modem.

Clear Password

This parameter allows you to erase the serial port (modem) password in case it has

been forgotten. Select Yes to keep the current password or No to erase it. Press

Enter to enable your selection.

Meter menu

There are six submenus under the Meter menu: Inputs, Outputs, Processing, ERL,

ERLE, and Default Meter. The meter selection determines what is shown on the front

panel peak-level LED display. When the meter is selected in the LCD menu tree, the

LCD displays peak level indications as well. Use the

▲ and ▼ buttons to select the

Meter menu, then scroll through the options and press Enter when you reach the

desired option.