Control/Status A Port Pinout (female)

Pin Definable

Type

Default

Description

1

Yes

Control

Lock front panel toggle

2

Yes

Status

Status of front panel lock

3

Yes

Control

Mute all mics toggle

4

Yes

Status

Status of mute all mics

5

Yes

C

Mute Output 9 toggle

6

Yes

S

Status of Output 9 mute

7

Yes

C

Mute Output 10 toggle

8

Yes

S

Status of Output 10 mute

9

Yes

C

Mute Output 11 toggle

10

Yes

S

Status of Output 11 mute

11

Yes

C

Mute Output 12 toggle

12

Yes

S

Status of Output 12 mute

13

Yes

C

Volume Up D Output 1 (1dB)

14 Yes

S

Not

programmed

15

Yes

C

Volume Down D Output 1

(1dB)

16 Yes

S

Not

programmed

17

No

S

Mic #1 Gate Status

18

No

S

Mic #2 Gate Status

19

No

S

Mic #3 Gate Status

20

No

S

Mic #4 Gate Status

21

No

S

Mic #5 Gate Status

22

No

S

Mic #6 Gate Status

23

No

S

Mic #7 Gate Status

24

No

S

Mic #8 Gate Status

25 No

Ground

Ground

Figure B.6. Control/Status Ports A, B

Control/Status connectors

The Control/Status connections are provided on two DB-25 connectors. These

connectors are labeled Control/Status A and Control/Status B and contain different

types of pins. The inputs on these connectors are internally pulled high and are

activated by connecting the pin to ground. The outputs are open collectors, which are

open when inactive and grounded when active. This allows the XAP 800 to control

and be controlled by a wide variety of external devices, including relays, lamps,

switches, and other equipment. Control pins on Control/Status A are momentary

while control pins on Control/Status B are latching.