REFSET - Reference channel setup

This command selects/reports the output the reference channel tracks.

Command form: DEVICE REFSET <Channel> <Group>[Value]

Argument details

Name

Description

Device

0–7 or * to select all units

REFSET

Command

Channel

1–4 (select Virtual Reference number)

Group

1–9 (select output channel to track)

Value

0 = none

Example:

#53 REFSET 2 4 On XAP 800 unit 3 (#53), virtual reference (2) will

track gain changes mde on output channel 4.

SERECHO - Serial Echo

This command selects/reports the serial echo of the RS-232 port.

Command form: DEVICE SERECHO [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SERECHO

Command

Channel

See Groups and Channels, page 97

Value

0 = Off, 1 = On, 2 = Toggle, Null = Current state

Example:

#54 SERECHO 1 On XAP 800 unit 4 (#54), the serial echo

(SERECHO) of the RS-232 port is set to on (1).

SERMODE - Serial Mode

This command selects/reports the serial mode of the RS-232 port.

Command form: DEVICE SERMODE [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SERMODE

Command

Value

1 = Text, 2 = Binary, Null = Current mode

Example:

#55 SERMODE 1 On XAP 800 unit 5 (#55), the RS-232 port serial

mode (SERMODE) is set to text (1).

Appendices

~ Appendix E: Serial Commands

If the serial mode is

changed, the terminal will

not see a response from

the unit, nor will the unit respond

to commands until the new status

is matched by the terminal.

✍ ✍