Xap 800 serial commands, Appendices ~ appendix e: serial commands – ClearOne XAP 800 User Manual

Page 103

Advertising
background image

97

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

XAP 800 Serial commands

Command

Function

AAMB

Selects/reports adapt ambient setting

AEC

Selects/reports acoustic echo canceller setting

AGC

Enable/disables AGC

AGCSET

Selects/reports AGC settings on inputs

AMBLVL

Selects/reports ambient level

BAUD

Selects/reports the baud rate of the serial port

CGROUP

Selects/reports compressor group setting

CHAIRO

Selects/reports chairman override setting

COMPRESS

Sets/reports compressor on audio processing

channel

COMPSEL

Selects/reports compressor activity for

processor

DECAY

Sets/reports decay rate

DELAY

Sets/reports delay rate

DELAYSEL

Selects/reports processor channel delay

DFLTM

Sets/reports default meter

DID

Selects/reports device ID

DSPVER

Reports DSP firmware version

FILTER

Selects/reports input/processor channel filter

setting

FILTSEL

Enables/disables filters on input/processor

channel

FLOW

Selects/reports the flow control of the serial

port

FMP

Sets/reports 1st Mic Priority for mic gating

group

FPP

Sets/reports current passcode setting

GAIN

Changes/reports gain for in, out, or process.

GATE

Reports gate status of channels 1–8

GHOLD

Selects/reports hold time setting

GMODE

Selects/reports gating mode setting

GOVER

Selects/reports gating override setting

GRATIO

Selects/reports gate ratio setting

GREPORT

Selects/reports gate status report frequency

GRPSEL

Selects/reports input gating group assignments

LABEL

Selects/reports label of specified channel

LFP

Sets/reports status of front panel access

Command

Function

LOCK

Selects/reports the state of the preset and

macro lock. When on, the lock prevents presets

and macros that have been flagged from being

altered in any way.

LOCKPRST

Selects/reports whether the lock is applied to a

preset or macro. If a preset or macro has the

lock applied, it can only be changed if the unit

is unlocked with the password.

LOCKPWD

Selects/reports the password for the

preset/macro lock. This can only be changed if

the unit is unlocked.

LMO

Selects/reports Last Mic On mode

LVL

Reports in, out, or processor level

LVLREPORT

Selects/reports level status

LVLRRATE

Sets the level report rate for the unit

MACRO

Executes macro or reports last macro

executed

MASTER

Reports the mode of the unit

MAX

Changes/reports max gain setting for in, out,

processor block

MDMODE

Enables/disables the modem mode for the unit

MIN

Changes/reports minimum gain setting for in,

out, processor block

MINIT

Sets/reports modem initialization string of

serial port

MINMAX

Changes/reports min and max gain from in,

out, processor block

MLINE

Selects/reports coarse gain adjustments on

Inputs 1–8

MMAX

Selects/reports max # of mics for each mic

group

MPASS

Sets passcode setting when using modem

mode

MTRX

Selects/reports matrix routing of an in. to out.

MTRXLVL

Selects/reports matrix level at the cross point

MUTE

Sets/reports mute status

NCD

Selects/reports noise cancellation amount for

each mic channel

Appendices

~ Appendix E: Serial Commands

Advertising