Gate - gate status, Ghold- gate hold time adjust, Appendices ~ appendix e: serial commands – ClearOne XAP 800 User Manual

Page 114: Argument details

Advertising
background image

Appendices

~ Appendix E: Serial Commands

108

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

GATE - Gate Status

This command reports the gate status of mics. This command is read only.

Command form: DEVICE GATE

Argument details

Name

Description

Device

0–7 or * to select all units

GATE

Command form

The command will return the gate status of mic inputs 1–8 in hexadecimal.

Example:

GHOLD- Gate Hold Time Adjust

This command selects/reports the setting of hold time.

Command form: DEVICE GHOLD <Channel> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

GHOLD

Command form

Channel

See Groups and Channels, page 97

Value

0.10-8.00 S

Null to return the current hold time

Example:

#50 GHOLD 1 .3 On XAP 800 unit 0 (#50), the hold time (GHOLD)

for mic channel 1 is 300ms (.3).

If

Hex # returned

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Mic 8

Mic 7

Mic 6

Mic 5

Mic 4

Mic 3

Mic 2

Mic 1

Mics 1 and 2 are gated on

0 3

0

0

0

0

0

0

1

1

Mics 1 and 3 are gated on

0 5

0

0

0

0

0

1

0

1

Mics 1, 4, and 7 are gated on

4 9

0

1

0

0

1

0

0

1

Mics 3–6 and 8 are gated on

B C

1

0

1

1

1

1

0

0

Hexadecimal Description

First digit

Second digit