5 Adjustments

5.7.2 Vibration Suppression Function Operating Procedure

5-68

7.

Set a frequency by using the

Import

function or by manually selecting the frequency.

Click

Import

. The value of the residual vibration frequency being monitored will be imported to the

Set

frequency

box. This function, however, is effective only when the residual vibration frequency is

between 1.0 and 100.0.

The

Set frequency

can be manually selected by clicking the setting arrows.

8.

Click

Set

.

If any vibration still occurs, manually make fine adjustments to the

Set frequency

, and click

Set

.

If you need to undo the change you made while making adjustments, click

Reset

. The setting will be

restored to the original value.