6 Utility Functions (Fn

)

6-34

3.

Click

Execute

.

The new settings for the vibration detection level will be shown in the boxes in lower section of the box.
The new settings will be saved in the SERVOPACK.

(3) Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-

cuting this function or of being changed automatically after executing this function.

• Parameters related to this function

These are parameters that are used or referenced when executing this function.

• Allowed changes during execution of this function

Yes : Parameters can be changed using SigmaWin+ while this function is being executed.

No : Parameters cannot be changed using SigmaWin+ while this function is being executed.

• Automatic changes after execution of this function

Yes : Parameter set values are automatically set or adjusted after execution of this function.

No : Parameter set values are not automatically set or adjusted after execution of this function.

MECHA

Parameter

Name

Mid-execution

changes

Automatic

changes

Pn311

Vibration Detection Sensitivity

Yes

No

Pn312

Vibration Detection Level

No

Yes

Advertising