Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 328

Advertising
background image

9 Appendix

9-46

Pn80A

100

1st Linear Acceleration Constant

Immediately

2

Pn80B

100

2nd Linear Acceleration Constant

Immediately

2

Pn80C

0

Acceleration Constant Switching
Speed

Immediately

2

Pn80D

100

1st Linear Deceleration Constant

Immediately

2

Pn80E

100

2nd Linear Deceleration Constant

Immediately

2

Pn80F

0

Deceleration Constant Switching
Speed

Immediately

2

Pn810

0

Exponential Function Acceleration/

Deceleration Bias

Immediately

2

Pn811

0

Exponential Function Acceleration/
Deceleration Time Constant

Immediately

2

Pn812

0

Movement Average Time

Immediately

2

Pn814

100

Final Travel Distance for External
Positioning

Immediately

2

Pn816

0000

Homing Mode Setting

Immediately

2

Pn817

50

Homing Approach Speed
(Homing Approach Speed 1)

Immediately

2

Pn818

5

Homing Creep Speed
(Homing Approach Speed 2)

Immediately

2

Pn819

100

Final Travel Distance for Homing

Immediately

2

Pn81E

0000

Input Signal Monitor Selection

Immediately

Pn81F

0010

Command Data Allocation

After restart

Pn820

0

Forward Latching Allowable Area

Immediately

Pn822

0

Reverse Latching Allowable Area

Immediately

Pn824

0000

Option Monitor 1 Selection

Immediately

Pn825

0000

Option Monitor 2 Selection Immediately

Pn827

100

Linear Deceleration Constant 1 for
Stopping

Immediately

2

Pn829

0

SVOFF Waiting Time (SVOFF at
deceleration to stop)

Immediately

Pn82A

1813

Option Field Allocation 1

After restart

Pn82B

1D1C

Option Field Allocation 2

After restart

Pn82C

1F1E

Option Field Allocation 3

After restart

Pn82D

0000

Option Field Allocation 4

After restart

Pn82E

0000

Option Field Allocation 5

After restart

Pn833

0000

Motion Setting

After restart

Pn834

100

1st Linear Acceleration Constant 2

Immediately

2

Pn836

100

2nd Linear Acceleration Constant 2

Immediately

2

∗2.

Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
operation.

Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or

the power must be turned OFF and then ON again.

(cont’d)

Parameter

Factory

Setting

Name

When

Enabled

Advertising