A.E63:
MECHATROLINK

Synchronization

Frame Not Received

Alarm

MECHATROLINK wiring is
incorrect.

Check the MECHATROLINK wir-
ings.

Correct the MECHATROLINK wir-
ing.

MECHATROLINK data recep-
tion error occurred due to noise
interference.

Take measures against noise. Check
the MECHATROLINK communi-
cations cable and FG wiring and
take measures such as adding ferrite

core on the MECHATROLINK
communications cable.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the

SERVOPACK.

A.EA2:
DRV Alarm 2

(SERVOPACK WDT

error)

MECHATROLINK transmission
cycle fluctuated.

Check the MECHATROLINK
transmission cycle setting.

Remove the cause of transmission
cycle fluctuation at host controller.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.Ed1:
Command Execution

Timeout

A timeout error occurred when

using an MECHATROLINK
command.

Check the motor status when the
command is executed.

Execute the SV_ON or SENS_ON
command only when the motor is
not running.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions