6.2 Alarm History Display (Fn000)

6-3

6

Utili

ty Fu

ncti

ons (Fn

)

6.2

Alarm History Display (Fn000)

This function displays the last ten alarms that have occurred in the SERVOPACK.

(1) Preparation

There are no tasks that must be performed before displaying the alarm history.

(2) Operating Procedure

Use the following procedure.

1.

In the SigmaWin+ main window, click

Alarm

-

Display Alarm

.

The

Alarm Display

dialog box will appear.

2.

Click the

Alarm traceback

tab to view the alarm history.

A list of past alarms can be viewed.

Note:

• If the same alarm occurs after more than one hour, the alarm will be saved. If it occurs in less than one hour, it

will not be saved.

• Delete the alarm history by clicking

Clear

. The alarm history is not cleared on alarm reset or when the SERVO-

PACK main circuit power is turned OFF.

MECHA

MECHA

Alarm number and Alarm name

Alarm history number
(The greater the number, the older the
alarm is.)