3.6.10 Correcting programming errors

Programming errors can be corrected easily in IDEC

SmartRelay :

• Provided editing mode is not yet closed, you can revert by

one step by pressing ESC.

• If you have already configured all inputs, simply

reconfigure the faulty input:

1. Move the cursor to the faulty position

2. Change to editing mode. Press OK

3. Enter the correct input circuit

You can only replace a block with a block that has exactly the

same number of inputs. However, you can delete the old block

and then insert a new one. You can choose any new block.

3.6.11 Selecting analog output values for RUN/STOP

transition

You can select the analog values that are output at the two

analog outputs when IDEC SmartRelay changes from RUN

mode to STOP mode.

In the programming menu:

1. Move the “>” cursor to ’Edit..’:

Press or

2. Select ’Edit’:

Press OK

3. Move the “>” cursor to ’AQ’:

Press or

4. Select ’AQ’:

Press OK

5. Move the “>” cursor to ’AQ in Stop’:

Press or

6. Select ’AQ in Stop’:

Press OK

IDEC SmartRelay shows the following display:

>Defined
Last
AQ in Stop
Last

The first two rows show your choices. The bottom row shows

the current setting for the analog output channels. The

default setting is ’Last’.

You can select either ’Defined’ or ’Last’. ’Last’ means that the

analog output values are held at their last value and ’Defined’

means that the analog output values are set to specific

values. When IDEC SmartRelay changes from RUN mode to

STOP mode, the values of the analog outputs change as

well, depending on the setting.
7. Select the desired output setting:

Press or .

8. Confirm your entry:

Press OK