IDEC FL1E SmartRelay User Manual

Page 229

Advertising
background image

IDEC SmartRelay functions

IDEC SmartRelay Manual

215

Functional description

If the input En is set, then the function sets the current level

to StSp + Offset ”B” for 100 ms.

Then, depending on the connection of Sel, the function runs

from the level StSp + Offset ”B” to either level 1 or level 2 at

the acceleration set in Rate.

If the input St is set, the function runs to a level of StSp +

Offset ”B” at the acceleration set in Rate. Then the function

holds the level at StSp + Offset ”B” for 100 ms. After 100 ms,

the level is set to Offset ”B”. The scaled value (output AQ) is

0.

If the input St is set, the function can only be restarted after

the inputs St and En have been reset.

If input Sel has been changed, depending on the connection

of Sel, the function runs from the current target level to the

new target level at the rate that is specified.

If the input En is reset, the function immediately sets the

current level to Offset ”B”.

The current level is updated every 100 ms. Note the

relationship between output AQ and the current level:

Output AQ = (current level - Offset ”B” / Gain ”A”)

Note

For further information on analog value processing please refer to
the online help for WindLGC.

Setting the Par parameter

View in programming mode (example):

B3 1+/
L1 =+04000
L2

B020

B3 2+/
MaxL=+7000
StSp=00222
Rate=00500

B3 3+/
A

=02.50

B

=–00300

p

=0

Press

Press

Gain
Offset

Decimals in the message text