Applications, Idec smartrelay manual 267 – IDEC FL1E SmartRelay User Manual

Page 281

Advertising
background image

Applications

IDEC SmartRelay Manual

267

Wiring of a lighting system with FL1E-H12RCC

The external wiring of a lighting system with an IDEC

SmartRelay is no different than it is for a conventional

stairway and corridor lighting system. Only the automatic

stairwell light switch/current impulse relay is replaced.

Supplementary functions are entered directly in IDEC

SmartRelay.

Current impulse relay with IDEC SmartRelay

Output Q1 is toggled with a pulse signal at input I1.

Automatic stairwell light switch with IDEC SmartRelay

Output Q1 is set for the duration of 6 minutes with a pulse

signal at input I1.

L1 N

I1

I3 I6 I7 I8

Q1

Q2

Q3

Q4

L

N

PE

I4

I5

I1 I2 I3

I1 I2 I3

Lamps

Switches

I1

Q1

x

Switch:

Lamps

I1

Q1

T

06:00m

Momentary

Switch:

Lights

Advertising