Parameter | Name:

C00919 | Moment of inertia from load

Data type: UNSIGNED_32

Index: 23656

d

= 5C68

h

From version 12.00.00

In order to take account of mass inertias changing during the process (e.g. reels) when optimising the response to

setpoint changes, the maximum value of the changing moment of inertia must be set here. The process signal

nInertiaAdapt_a of the

LS_MotorInterface

SB can then be used in the process to dynamically control what

percentage of it is to be taken into account for the setpoint feedforward control.
Setting range

(min. value | unit | max. value)

0.00

kg cm^2

6000000.00

Subcodes

Lenze setting

Info

C00919/1

0.00 kg cm^2

Load moment of inertia

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00922 | ICM_DiagnosticCounter

Data type: UNSIGNED_16

Index: 23653

d

= 5C65

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00937 | Field-oriented motor currents

Data type: INTEGER_16

Index: 23638

d

= 5C56

h

From version 11.00.00

Field weakening for synchronous motors

Display range

(min. value | unit | max. value)

-320.00

A

320.00

Subcodes

Info

C00937/1

Field-producing current

C00937/2

Torque-producing current

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00938 | PSM: Maximum motor current field weakening

Data type: UNSIGNED_16

Index: 23637

d

= 5C55

h

From version 11.00.00

Field weakening for synchronous motors

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

500.00 30.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00939 | Ultimate motor current

Data type: UNSIGNED_16

Index: 23636

d

= 5C54

h

From version 10.00.00

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

A

3000.0 3000.0 A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10