Page 885: C00420, C00420/2, C00423/3, C00423/4, C00423/5, C00423/6, C00423/7

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

885

15

Parameter reference

15.2

Parameter list | C00420

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00420

C00423

Parameter | Name:

C00420 | Number of encoder increments

Data type: UNSIGNED_16

Index: 24155

d

= 5E5B

h

Indication of the encoder constant

Encoder/feedback system

Setting range

(min. value | unit | max. value)

1

Incr./rev.

32767

Subcodes

Lenze setting

Info

C00420/1

128 incr./rev.

FreqIn12: Encoder increment

C00420/2

128 incr./rev.

FreqIn67: Encoder increment

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00423 | DOx: Delay times

Data type: UNSIGNED_16

Index: 24152

d

= 5E58

h

Delay times for the digital output terminals

Digital output terminals

Setting range

(min. value | unit | max. value)

0.000

s

65.000

Subcodes

Lenze setting

Info

C00423/1

0.000 s

Relay ON delay

C00423/2

0.000 s

Relay OFF delay

C00423/3

0.000 s

DO1 ON delay

C00423/4

0.000 s

DO1 OFF delay

C00423/5

0.000 s

DO2 ON delay

C00423/6

0.000 s

DO2 OFF delay

C00423/7

0.000 s

DO3 ON delay

C00423/8

0.000 s

DO3 OFF delay

C00423/9

0.000 s

DO "High Current" ON delay

C00423/10

0.000 s

DO "High Current" OFF delay

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT