C00701

Parameter | Name:

C00701 | LA_NCtrl: Digital connection list

Data type: UNSIGNED_16

Index: 23874

d

= 5D42

h

Connection parameters for "Actuating drive speed" application: Binary inputs

• Selection of the binary output signals to be connected to the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the

subcodes.

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00701/1

0: Not connected

LA_NCtrl

: bCInh

Control input for setting controller inhibit

C00701/2

16008: LS_DigitalInput: bCInh

LA_NCtrl

: bFailReset

Control input for error acknowledgement

C00701/3

0: Not connected

LA_NCtrl

: bSetQuickstop

Control input for quick stop request

C00701/4

16002: LS_DigitalInput: bIn3

LA_NCtrl

: bSetDCBrake

Control input for DC-injection braking request

C00701/5

0: Not connected

LA_NCtrl

: bRFG_Stop

Control input for stopping the speed ramp function

generator

C00701/6

0: Not connected

LA_NCtrl

: bRFG_0

Control input for setting the speed ramp function

generator to 0

C00701/7

0: Not connected

Reserved

C00701/8

16003: LS_DigitalInput: bIn4

LA_NCtrl

: bSetSpeedCcw

Control input for change of direction of rotation

C00701/9

16000: LS_DigitalInput: bIn1

LA_NCtrl

: bJogSpeed1

Selection input for fixed setpoints

C00701/10

16001: LS_DigitalInput: bIn2

LA_NCtrl

: bJogSpeed2

Selection input for fixed setpoints

C00701/11

0: Not connected

LA_NCtrl

: bJogSpeed4

Selection input for fixed setpoints

C00701/12

0: Not connected

LA_NCtrl

: bJogSpeed8

Selection input for fixed setpoints

C00701/13

0: Not connected

LA_NCtrl

: bJogRamp1

Selection input for additional acceleration/deceleration

times

C00701/14

0: Not connected

LA_NCtrl

: bJogRamp2

Selection input for additional acceleration/deceleration

times

C00701/15

0: Not connected

LA_NCtrl

: bJogRamp4

Selection input for additional acceleration/deceleration

times

C00701/16

0: Not connected

LA_NCtrl

: bJogRamp8

Selection input for additional acceleration/deceleration

times

C00701/17

0: Not connected

LA_NCtrl

: bMPOTInAct

Control input for deactivation of motor potentiometer

C00701/18

0: Not connected

LA_NCtrl

: bMPOTUp

Control input for motor potentiometer ramp-up

C00701/19

0: Not connected

LA_NCtrl

: bMPOTDown

Control input for motor potentiometer ramp-down