17 function library – Lenze 8400 HighLine User Manual

Page 1468

Advertising
background image

17

Function library

17.1

Function blocks

1468

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

dnOut32_p

DINT

Integrator value (32 bits)

bOvfl32

BOOL

Status signal "overflow (32 bits)"

TRUE Overflow

nOut16

INT

Integrator value (16 bits)

bOvfl16

BOOL

Status signal "overflow (16 bits)"

TRUE Overflow

bInitDone

BOOL

Status signal "Initialisation completed"

TRUE Integrator is initialised

nSpeedGearAdd_v

INT

Resulting speed with additive speed

(nSet_v * gearbox factor + nSpeedAdd_v)

nSpeedGear_v

INT

Resulting speed without additive speed

(nSet_v * gearbox factor)

Parameter

Possible settings

Info

C01067/1

Invert. gearbox nSet_v

0 not inverted
1 inverted
2 Automatically from MCK

Advertising