C01035 | l_curve_3: selectcurve, C01040 | l_srfg_1 linear ramp time, C01041 | l_srfg_1 s-ramp time – Lenze 8400 HighLine User Manual

Page 1038: 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C01035

1038

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01035

C01040

C01041

Parameter | Name:

C01035 | L_Curve_3: SelectCurve

Data type: UNSIGNED_16

Index: 23540

d

= 5BF4

h

From version 12.00.00

FB

L_Curve_3

: Selection of the tensile force profile

Selection list

Info

0 Linear tensile force profile

Use of L_Curve_3 for tensile force characteristic

1 Linear torque characteristic
2 Tensile force profile according to

characteristic

Subcodes

Lenze setting

Info

C01035/1

0: Linearer Zugkraftverlauf

L_Curve_3

: SelectCurve

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01040 | L_SRFG_1..2 linear ramp time

Data type: UNSIGNED_32

Index: 23535

d

= 5BEF

h

From version 04.00.00

Symmetrical acceleration/deceleration time for the ramp function generator
Setting range

(min. value | unit | max. value)

0.001

s

999.999

Subcodes

Lenze setting

Info

C01040/1

100.000 s

L_SRFG_1

: linear ramp time

C01040/2

100.000 s

L_SRFG_2

: linear ramp time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01041 | L_SRFG_1..2 S-ramp time

Data type: UNSIGNED_32

Index: 23534

d

= 5BEE

h

From version 04.00.00

S-ramp time for jerk-free acceleration
Setting range

(min. value | unit | max. value)

0.001

s

50.000

Subcodes

Lenze setting

Info

C01041/1

0.200 s

L_SRFG_1

: S-ramp time

C01041/2

0.200 s

L_SRFG_2

: S-ramp time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Advertising