C00712 | la_tabpos: phi connection list, C00712, 15 parameter reference – Lenze 8400 HighLine User Manual

Page 958

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00712

958

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00712

C00711/43

0: Not connected

LA_TabPos

: bMckOperationMode_4

Control input for MCK operating mode changeover value

4

C00711/44

0: Not connected

LA_TabPos

: bMckOperationMode_8

Control input for MCK operating mode changeover value

8

C00711/45

0: Not connected

LA_TabPos

: bPosProfileNo_1

Control input for selection of profile number value 1

C00711/46

0: Not connected

LA_TabPos

: bPosProfileNo_2

Control input for selection of profile number value 2

C00711/47

0: Not connected

LA_TabPos

: bPosProfileNo_4

Control input for selection of profile number value 4

C00711/48

0: Not connected

LA_TabPos

: bPosProfileNo_8

Control input for selection of profile number value 8

C00711/49

0: Not connected

LA_TabPos

: bFreeIn1

Input for binary user signal 1

C00711/50

0: Not connected

LA_TabPos

: bFreeIn2

Input for binary user signal 2

C00711/51

0: Not connected

LA_TabPos

: bFreeIn3

Input for binary user signal 3

C00711/52

0: Not connected

LA_TabPos

: bFreeIn4

Input for binary user signal 4

C00711/53

0: Not connected

LA_TabPos

: bFreeIn5

Input for binary user signal 5

C00711/54

0: Not connected

LA_TabPos

: bFreeIn6

Input for binary user signal 6

C00711/55

0: Not connected

LA_TabPos

: bFreeIn7

Input for binary user signal 7

C00711/56

0: Not connected

LA_TabPos

: bFreeIn8

Input for binary user signal 8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00711 | LA_TabPos: Digital connection list

Data type: UNSIGNED_16

Index: 23864

d

= 5D38

h

Parameter | Name:

C00712 | LA_TabPos: phi connection list

Data type: UNSIGNED_16

Index: 23863

d

= 5D37

h

Connection parameters for "Table positioning" application: 32-bit inputs

• Selection of the 32-bit output signals for connection with the 32-bit input signals

• The selection list contains all 32-bit output signals which can be assigned to the 32-bit inputs mapped by the

subcodes.

Selection list
See

selection list - angle signals

Subcodes

Lenze setting

Info

C00712/1

0: Not connected

LA_TabPos

: dnPosProfilePosition

Input for selecting the target position in [increments]

C00712/2

0: Not connected

LA_TabPos

: dnFreeIn1

Input for 32-bit user signal 1

C00712/3

0: Not connected

LA_TabPos

: dnFreeIn2

Input for 32-bit user signal 2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1