C00720 | l_digitaldelay_1: delay, C00721 | l_digitaldelay 2 : delay, C00720/1 – Lenze 8400 HighLine User Manual

Page 959: C00720/2, 15 parameter reference

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

959

15

Parameter reference

15.2

Parameter list | C00715

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00715

C00716

C00717

C00720

C00721

Parameter | Name:

C00715 | LA_TabPos_Out: Analog signal list

Data type: UNSIGNED_16

Index: 23860

d

= 5D34

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00716 | LA_TabPos_Out: Digital signal list

Data type: UNSIGNED_16

Index: 23859

d

= 5D33

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00717 | LA_TabPos_Out: phi signal list

Data type: UNSIGNED_16

Index: 23858

d

= 5D32

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00720 | L_DigitalDelay_1: Delay

Data type: UNSIGNED_32

Index: 23855

d

= 5D2F

h

Switch-on/off delay time
Setting range

(min. value | unit | max. value)

0.000

s

3600.000

Subcodes

Lenze setting

Info

C00720/1

0.000 s

L_DigitalDelay_1

: ON delay

C00720/2

0.000 s

L_DigitalDelay_1

: OFF delay

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00721 | L_DigitalDelay 2..3: Delay

Data type: UNSIGNED_32

Index: 23854

d

= 5D2E

h

Switch-on/off delay time
Setting range

(min. value | unit | max. value)

0.000

s

3600.000

Subcodes

Lenze setting

Info

C00721/1

0.000 s

L_DigitalDelay_2

: ON delay

C00721/2

0.000 s

L_DigitalDelay_2

: OFF delay

C00721/3

0.000 s

L_DigitalDelay_3

: ON delay

C00721/4

0.000 s

L_DigitalDelay_3

: OFF delay

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000