C00585 | resp. to motor overtemp. ptc, C00586 | resp. to open circuit htl encoder, C00588 | resp. to max. speed at switching freq – Lenze 8400 HighLine User Manual

Page 919: C00586, C00585, Is activated, Tting, Fault"), mo, C00582, In the lenze setting, no

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

919

15

Parameter reference

15.2

Parameter list | C00582

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00582

C00585

C00586

C00588

Parameter | Name:

C00582 | Resp. to heatsink temp. > shutdown temp. -5°C

Data type: UNSIGNED_8

Index: 23993

d

= 5DB9

h

Response if the heatsink temperature has reached the switch-off temperature threshold.
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00585 | Resp. to motor overtemp. PTC

Data type: UNSIGNED_8

Index: 23990

d

= 5DB6

h

Response to motor overtemperature

• The motor temperature is measured by means of a PTC thermistor at terminal X106.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00586 | Resp. to open circuit HTL encoder

Data type: UNSIGNED_8

Index: 23989

d

= 5DB5

h

Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00588 | Resp. to max. speed at switching freq.

Data type: UNSIGNED_8

Index: 23987

d

= 5DB3

h

Response if the maximum speed for the set inverter switching frequency is reached (

C00018

)

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1