157 l_signalswitch_4, 157 l_signalswitch_4 5, L_signalswitch_4 – Lenze 8400 HighLine User Manual
Page 1495: 17 function library
Advertising
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1495
17
Function library
17.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.157
L_SignalSwitch_4
This FB switches between two input signals of the "WORD" data type. The switch-over is controlled
by means of a boolean input signal.
Inputs
Outputs
Identifier
Data type
Information/possible settings
wIn1
WORD
Input signal 1
wIn2
WORD
Input signal 2
bSet
BOOL
Selection of the input signal for the output at wOut
FALSE wIn1
TRUE wIn2
Identifier
Data type
Value/meaning
wOut
WORD
Output signal
/B6LJQDO6ZLWFKB
Z,Q
Z2XW
Z,Q
E6HW
Advertising