C00003 | status of last device command, C00003, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 799
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
799
15
Parameter reference
15.2
Parameter list | C00003
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00003
C00002/32
0: Off / ready
Check password
•
From version 06.00.00
C00002/33
0: Off / ready
Delete password
•
From version 06.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD
h
Parameter | Name:
C00003 | Status of last device command
Data type: UNSIGNED_8
Index: 24572
d
= 5FFC
h
Status of the device command executed last (
Note:
Before switching off the supply voltage after carrying out a device command, check whether the device command
has been carried out successfully via the status display!
:
Selection list
(read only)
Info
0 Successful
Device command has been executed successfully.
1 Command unknown
Device command implausible or unknown to the system.
2 Password protection
Unauthorised access for requested device command.
3 Time-out
Device command could not be processed in the defined
time (timeout).
4 System fault
5 Command server assigned
6 Controller inhibit required
10 Memory module binding error
11 Password too short
12 Wrong password
13 Password already set
14 Password not assigned
20 Setting the hiperface position failed
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1