Parameter

Definition of the blocking zones
Up to three zones can be parameterised which are to be skipped by the nOut_a output signal.
The example below shows the parameter setting of two blocking zones for the L_NLim_1 FB:

[17-51] Zone masking by means of parameterisable blocking zones (in our example: L_NLim_1)

• The parameterised blocking zones have the same effect on negative input signals.
• A blocking zone is deactivated by entering identical limit values (in our example: blocking zone

3).

Parameter

Possible settings

Info

C00807/1...3

0.00

%

199.99 Max. skip frequency 1 ... 3

• Lenze setting: 0.00 %

C00808/1...3

0.00

%

199.99 Min. skip frequency 1 ... 3

• Lenze setting: 0.00 %

Parameter

Blocking zone 1

Blocking zone 2

Blocking zone 3

Minimum limit value

C00808/1: 48 %

C00808/2: 138 %

C00808/3: 0 %

Maximum limit value

C00807/1: 104 %

C00807/2: 178 %

C00807/3: 0 %

Blocking zone 1

Blocking zone 2

nOut_a [%]

nIn_a
[%]

1

0

199.99

-199.99

-199.99

199.99

C00807/1

C00808/1

48

138

0

1

104

178

C00807/2

C00808/2