3 loading the oscillogram, Loading the oscillogram, Loading the oscillogram ( 684) – Lenze 8400 HighLine User Manual

Page 684: 10 oscilloscope function

Advertising
background image

10

Oscilloscope function

10.4

Managing oscillograms (measured data sets)

684

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.4.3

Loading the oscillogram

Configurations/data sets already stored can be reloaded into the oscilloscope any time, e.g. for the

overlay function.

How to load a data set from the project:

1. Click the

icon in the oscilloscope toolbar.

• The Load data set dialog box appears.

2. Select the data set to be loaded from the upper list field.
3. If the data set is to be used as a configuration, select the option as configuration....
4. Click Open.

• The dialog box is closed and the selected data set/configuration is loaded.
• If the configuration to be loaded contains variables that are no longer available in the

controller, these variables are automatically removed from the configuration.

How to import a data set from a file:

1. Click the

icon in the oscilloscope toolbar.

• The Load data set dialog box appears.

2. Click the Search... button.
3. Select the file to be imported within the desktop environment from the Open dialog box.
4. If the data set is to be used as a configuration, select the option as configuration....
5. Click Open.

• The dialog box is closed and the selected data set/configuration is imported.
• If the configuration to be loaded contains variables that are no longer available in the

controller, these variables are automatically removed from the configuration.

Note!

The reuse of a saved configuration is only reasonable for controllers of the same type, as

otherwise due to a scaling of the oscilloscope channels that is not adapted, incorrect

values are displayed!