17 function library – Lenze 8400 HighLine User Manual
Page 1546
17
Function library
17.2
System blocks
1546
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
Note!
The real length of the low or high level at the bSquareWave output is always 1 ms higher
than set in
or
. If "0 ms" is set, a level with a length of 1 ms is created
length, for instance, and if "1000 ms" is set, a level with a length of 1001 ms is created.
Parameter
Possible settings
Info
0
ms
60000 Length of the low level (break) + 1 ms
• For output bSquareWave
• Lenze setting: 1000 ms
0
ms
60000 Length of the high level + 1 ms
• For output bSquareWave
• Lenze setting: 1000 ms
(from version 06.00.00)
0
ms
60000 Delay of the status bFirstCycleDone
• Lenze setting: 100 ms