C00490 | position encoder selection, C00495 | speed sensor selection, C00496 | encoder evaluation method digin12 – Lenze 8400 HighLine User Manual

Page 906: C00490, Select "encoder, C00495, This setting is, C00496, This se, In12" in

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00490

906

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00490

C00495

C00496

Parameter | Name:

C00490 | Position encoder selection

Data type: UNSIGNED_8

Index: 24085

d

= 5E15

h

Selection of the feedback system for the generation of the actual position on the load

Encoder/feedback system

Selection list

(Lenze setting printed in bold)

Info

0 No sensor: nSpeedSetValue_a

No encoder available on the load.

The position signal dnMotorPosAct_p is derived from the

speed setpoint nSpeedSetValue_a.

1 Sensor signal FreqIn12

Position encoder signal is fed via digital inputs DI1 and

DI2

2 Encoder signal FreqIn67

Position encoder signal is fed via digital inputs DI6 and

DI7

5 Encoder signal FreqIn1267

From version 15.00.00

Position encoder signal is fed via digital inputs DI1/DI2

and DI6/DI7 (connection of 4-track HTL encoders)

10 Encoder selection C495 or

nVoltageAngleAct_a

From version 12.00.00

The position signal dnMotorPosAct_p is either calculated

from the set speed feedback (for

C00495

> 0) or from the

speed signal nMotorSpeedAct_v (for

C00495

= 0).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00495 | Speed sensor selection

Data type: UNSIGNED_8

Index: 24080

d

= 5E10

h

Selection of the feedback system for the actual speed for motor control and display

Encoder/feedback system

Selection list

(Lenze setting printed in bold)

Info

0 No sensor

No sensor available for the actual speed detection

1 Sensor signal FreqIn12

Speed sensor signal is fed via the digital DI1 and DI2

inputs

2 Encoder signal FreqIn67

Speed encoder signal is fed via digital inputs DI6 and DI7

5 Encoder signal FreqIn1267

From version 15.00.00

Speed encoder signal is fed via digital inputs DI1/DI2 and

DI6/DI7 (connection of 4-track HTL encoders)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00496 | Encoder evaluation method DigIn12

Data type: UNSIGNED_8

Index: 24079

d

= 5E0F

h

Encoder/feedback system

Selection list

(Lenze setting printed in bold)

Info

0 High-resolution encoders

High-precision procedure for high-resolution encoders

(>=512 increments)

1 Low-resolution encoder (StateLine)

High-precision procedure for low-resolution encoders

(<=128 increments)

2 Comb. encoder procedure

Combination of the first two procedures as a function of

the speed (recommended procedure)

3 Edge-counting procedure

Simple edge counting procedure with adjustable

scanning time (

C00425

)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising