HL-L3270CDW

Error Message

Cause

Action

2-sided Disabled

The back cover of the machine is
not closed completely.

Close the back cover of the machine until it
locks in the closed position.

Access Denied

The function you want to use is
restricted by Secure Function
Lock 3.0.

Ask your administrator to check your Secure
Function Lock Settings.

Calibration

Calibration failed.

Press and hold down

to turn off the

machine. Wait a few seconds, and then
turn it on again. Perform the color
calibration again using the LCD.

Install a new belt unit.

If the problem continues, contact Brother
Customer Service or your local Brother
dealer.

Cartridge Error

The toner cartridge is not installed
correctly.

Remove the toner cartridge and drum unit
assembly for the color that is indicated on the
LCD. Take out the toner cartridge, and put it
back into the drum unit again. Install the toner
cartridge and drum unit assembly back in the
machine.
If the problem continues, contact Brother
Customer Service or your local Brother dealer.

Condensation

Condensation may have formed
inside the machine after a room
temperature change.

Leave the machine turned on. Wait for 30
minutes with the top cover in the open
position. Then turn off the machine and close
the cover. Turn it on again.

Cooling Down

The temperature of the inside of
the machine is too hot. The
machine pauses its current print
job and goes into cooling down
mode.

Wait until the machine has finished cooling
down. Make sure all vents on the machine are
clear of obstructions.
When the machine has cooled down, it will
resume printing.

Cover is Open

The top cover is not completely
closed.

Open and then firmly close the top cover of the
machine.

Cover is Open

The fuser cover is not completely
closed.

Close the fuser cover located inside the back
cover of the machine.

Drum !

The corona wires on the drum unit
must be cleaned.

Clean the corona wires on the drum unit.

See

Related Information

:

Clean the Corona

Wires

.

If the problem continues, replace the drum unit
with a new one.

Drum Stop

It is time to replace the drum unit.

Replace the drum unit.
See

Related Information

:

Replace the Drum

Unit

.

Jam 2-sided

The paper is jammed underneath
the paper tray or the fuser unit.

Remove the paper tray or open the back cover
to gently remove the jammed paper.