84

Granit XP User Guide

Trigger Number

This sets the number of trigger presses required to activate the Trigger Toggle
Mode.

Default is 3

.

Trigger Timing

This sets the timing of the trigger presses in order to qualify as a trigger toggle,
rather than a regular trigger press. After scanning the

Trigger Timing

barcode, set

the time-out duration (from 50-2,000 milliseconds) by scanning digits from the

Programming Chart,

beginning on page 289, then

Save

.

Default = 400ms.

Trigger Toggle Timeout

This sets the length of time the scanner stays in trigger toggle mode before revert-
ing to scan mode. After scanning the

Trigger Toggle Timeout

barcode, set the

time-out duration (from 0 to 65 seconds) by scanning digits from the

Programming Chart,

beginning on page 289, then

Save

.

Default = 5 seconds.

Note:

If this is set to 0, you must repeat the toggle sequence to return to the default
scanning mode. For example, if 2 quick trigger presses puts the scanner into
centering mode and the Trigger Timing is 0, you would have to do 2 quick presses
again to go back to the default scanning mode.

2 Quick Triggers

*3 Quick Triggers

4 Quick Triggers

Trigger Timing

Trigger Toggle Timeout