Granit XP User Guide

73

by this setting. After the maximum number of attempts is reached, the scanner will
not attempt to reconnect to a base or an Access Point. Pressing the trigger, scan-
ning an Access Point linking barcode, or placing the scanner in the cradle resets
the attempt count and the scanner will again try to link.

Scan the

Maximum Link Attempts

barcode, then scan the number of attempts for

the setting (from 0-100) from the

Programming Chart,

beginning on page 289,

then

Save

.

Default = 0.

Note:

When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause
the scanner to try to link until the Power Time-Out Timer setting expires. When Auto
Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause the
scanner to only attempt linking one time after a trigger press.

Relink Time-Out

Relink Time-Out controls the idle time between relink attempts. An attempt to link
a scanner to a base or an Access Point typically lasts up to 5 seconds. This is the
time when the scanner is actually attempting a contact. Relink Time-Out controls
the amount of time, in seconds, that elapses between the end of one connection
attempt and the start of the next.

Note:

The length of time for an attempt depends on the number of scanners connected to
a base unit or Access Point. An extra 7 seconds may be required when a connection is
successful.

Scan the

Relink Time-Out

barcode, then scan the number of seconds for the set-

ting (from 1-100) from the

Programming Chart,

beginning on page 289, then

Save

.

Default = 3 seconds.

Bluetooth/ISM Network Activity Examples

Default values

When the scanner goes out of range, the scanner repeatedly attempts to connect
to the base unit or Access Point. Each attempt consists of approximately 5 seconds
of active time followed by 3 seconds of idle time. After one hour, the scanner pow-
ers off and batch mode data is lost.

Example:

Maximum Link Attempts set to 15
Other values at default setting

Maximum Link Attempts

Relink Time-Out

Advertising