Replace cables and batteries in cordless systems, Replace an interface cable in a base, Change a scanner battery – Honeywell Granit 1991iSR Ultra-Rugged Standard-Range Barcode Scanner User Manual

Page 289: Troubleshoot a corded scanner

Advertising
background image

Granit XP User Guide

273

Replace Cables and Batteries in Cordless Systems

Replace an Interface Cable in a Base

1. Turn the power to the host system OFF.

2. Disconnect the base’s cable from the terminal or computer.

3. Turn the base upside down.

4. Pull the connector out while maintaining pressure on the connector release

clip.

5. Replace with the new cable. Insert the connector into the opening and press

firmly. The connector is keyed to go in only one way, and will click into place.

Change a Scanner Battery

1. Rotate metal twist at bottom of battery door counterclockwise.

2. Remove battery.

3. Insert replacement battery.

4. Replace end cap and screw together.

Troubleshoot a Corded Scanner

The scanner automatically performs self-tests whenever you turn it on. If your
scanner is not functioning properly, review the following Troubleshooting Guide to
try to isolate the problem.

Is the power on? Is the aimer on?

If the aimer isn’t illuminated, check that:

The cable is connected properly.

The host system power is on (if external power isn’t used).

The trigger works.

Is the scanner having trouble reading your symbols?

If the scanner isn’t reading symbols well, check that the symbols:

Aren’t smeared, rough, scratched, or exhibiting voids.

Aren’t coated with frost or water droplets on the surface.

Are enabled in the scanner or in the decoder to which the scanner connects.

Advertising