Granit XP User Guide

Auto Reconnect Mode

Auto Reconnect controls whether or not the scanner automatically begins the
relink process when a loss of connection is detected. When the

Auto Reconnect On

barcode is scanned, the scanner begins the relink process immediately, without
user intervention.

Default = Auto Reconnect On.

The table below shows the results of the Auto Reconnect On and Off settings:

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scanner
tries to form a connection with a base or an Access Point. During the connection
setup process, the scanner transmits in order to search for and connect to a base
or an Access Point. In order to prevent continuous transmissions that could inter-
fere with other users of the ISM band, the number of attempts to connect is limited

Event

Auto Reconnect On

Auto Reconnect Off

Scanner out of range

Relink occurs automatically. If
maximum number of link attempts
is unsuccessful, then the scanner
must be relinked by either pulling
the trigger, placing the scanner in
the base, or scanning the Access
Point linking barcode. (See

Maximum Link Attempts

on page

72.)

The scanner is relinked by
pulling the trigger, or scanning
the Access Point linking
barcode.

Base or Access point reset
(firmware upgrade or power
cycle)

Scanner behaves as if out of range.

No attempt to relink made
while base or Access Point is
powered off. Trigger must be
pulled to initiate relinking.

Scanner power down due to
Power Time-Out Timer
setting

Trigger must be pulled, Access Point linking barcode must be
scanned, or the scanner must be placed in the base unit to relink.
(Note: Scanner re-links on power up, but powers on due to one of the
above actions.)

Scanner reset due to
firmware upgrade

Relink occurs automatically.

Scanner reset due to battery
or charge pack change

Relink occurs automatically.

Scanner placed in different
base unit

Relink to new base occurs automatically.

* Auto Reconnect On

Auto Reconnect Off