Granit XP User Guide

Don’t Require 5 Digit Addenda

: If you have selected Require 5 Digit Addenda, and

you want to disable this feature, scan

Don’t Require 5 Digit Addenda

. EAN-13 bar-

codes are transmitted, depending on the setting you are using for

EAN/JAN-13

Addenda Required

.

Default = Don’t Require 5 Digit Addenda.

EAN-13 Beginning with 378/379 Addenda Required

This setting programs the scanner to require any combination of a 2 digit addenda
or a 5 digit addenda on EAN-13 barcodes that begin with a “378” or “379.” The fol-
lowing settings can be programmed:

Require Addenda

: All EAN-13 barcodes that begin with a “378” or “379” must have

a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-
13 barcode with the addenda is then transmitted as a single, concatenated bar-
code. If the required addenda is not found within the

Addenda Timeout

period, the

EAN-13 barcode is discarded.

Don’t Require Addenda

: If you have selected Require Addenda, and you want to

disable this feature, scan

Don’t Require Addenda

. EAN-13 barcodes are transmit-

ted, depending on the setting you are using for

EAN/JAN-13 Addenda Required

.

Default = Don’t Require Addenda.

* Don’t Require 5 Digit Addenda

Require 5 Digit Addenda

* Don’t Require Addenda

Require 2 Digit Addenda

Require 5 Digit Addenda

Require 2 or 5 Digit Addenda