Clarity

Timing

Operator Manual

Page 99

attributes by clicking the attributes to be included.You can select them individually or they are
multi-selectable with Function + click.

Below the filter attributes are the Timing Controls. The detail shown in the Timing Control can
be varied by clicking on either:

Compact: one line is used for all devices of that type

Capped: the height of the Timing Control is limited to a maximum of 5 lines – the
individual value rectangles are compressed to fit into the available space.

Expanded: the Timing Control is expanded to suit the number of selected devices.

See section 10.8 for more details.

Clicking on the Fade Curves icon reveals a range of fade curves to choose from as
described below.

Clicking on Menu reveals a range of choices to set, reset, align and straighten times and
to recall preset times or save preset times as described below.

15.5 SETTING TIMES
The delay time, fade time and total time (delay + fade) are shown in the Timing Control. When
times are altered the display automatically zooms to show the entire duration.



The Timing Control is divided into a grid of 9 time boxes as indicated by the dotted lines in the
Timing Control. As you move over each time box, the cursor changes to indicate how the timing

will be affected if you drag in each section. Touching (or clicking) and dragging in one the
relevant box performs the following actions:

Skew delay time from
top to bottom without

changing duration.

Skew delay time top to

bottom.

Skew fade from top

to bottom.

Change delay time

without changing

duration.

Change delay time.

Change fade time.

Skew delay from

bottom to top without

changing duration.

Skew delay time bottom to

top.

Skew fade from time

bottom to top.


Double clicking and holding Function or holding [Shift] on the keyboard whilst dragging gives

finer control.

15.5.1 Setting Times by Direct Entry

Double-clicking in the left, middle or right centre boxes of a Timing Control brings up an
entry box where you can key in either the delay, fade or duration times respectively on

the numeric keypad, then press Enter.

Right-clicking in the left column displays a menu where you can choose to:

Set delay times.
Align delay times that have been skewed.

Equalize uneven skewed delay times.