23 Command Line Programming

23.1 OVERVIEW
You can use command line programming to directly select fixtures, groups, presets and set

intensity levels and fade times.
If you type in a (fixture unit) number on the keypad, the “command line” automatically appears
at the bottom of the encoder wheel touch screen. You can select multiple fixtures and enter

intensity and fade time values as described below.

23.2 FIXTURE SELECTION
A Fixture can be selected by keying in a fixture unit number (see fixture unit numbering below)

followed by Enter.
For example:

22 Enter selects fixture 22.

A range of fixture unit numbers can be selected by using either the Thru/ key and you can

also combine and subtract ranges using + and -.
For example:

1 Thru/ 10 Enter (selects fixtures 1 through 10).
1 Thru/10 + 20 Thru/ 30 Enter (selects fixtures 1 through 10 plus 20 through 30).

1 Thru/ 30 - 11 Thru/ 19 Enter (selects fixtures 1 through 30 except 11 through 19).

The order of number entry is respected so that ….....
5 Thru/ 1 + 6 Thru/ 10 Enter, will get a fixture selection order of 5, 4, 3, 2, 1, 6, 7, 8, 9,
10.


If you omit the end of the range, then Clarity defaults to the highest fixture unit number of the

same type of fixture.
For example:

1 Thru/ Enter will select all fixtures of the same type as fixture 1.
10 Thru/ Enter
will select all fixtures of the same type as fixture 10 with fixture numbers

above 10.

23.3 INTENSITY ENTRY
You can follow you fixture selection entry (above) with @ (used as the command “AT”) and

specify a percentage intensity level, On/Full for full or just Enter to default to full.
For example:

1 Thru/ 10 @ 100 Enter
1 Thru/ 10 @
On/Full Enter

1 Thru/ 10 @ Enter

…..all of these commands set fixtures 1 through 10 at 100%

intensity.


You can also specify a range or a set of intensity levels.
For example:

1 Thru/ 10 @ 50 Thru/ 100 (1 through 10 at 50 through 100), will result in an intensity fan
from 50% to 100% over fixtures 1 through 10.

1 Thru/ 10 @ 50 + 70 (1 through 10 at 50 plus 70) will set alternate fixtures at 50% and
70% (50,70,50,70 etc.).


Single digit values are also accepted as a shortcut value.

For example:
1 Thru/ 10 @ 5 Enter will set fixtures 1 through 10 at 50%.

Previously selected fixtures can be given an intensity.