7 skip intervening events – LSC Lighting CLARITY LX Series v.1 User Manual

Page 227

Advertising
background image

Clarity

Timelines

Operator Manual

Page 217

When Recede is enabled (default), events will follow the absolute value of the Timecode in both
directions of time. If the Timecode jumps back in time, the events will follow.

When “Recede” is NOT enabled, events will only follow forward changes in Timecode.

For example, if recede is enabled, an event to trigger cue 2 at 0:0:10:0 will trigger cue 2 when

the Timecode first becomes later than 0:0:10:0 and will trigger cue 1 when the Timecode first
becomes earlier than 0:0:10:0.

Receding from the first cue in a cue-list will release the cue-list.

33.9.7 Skip Intervening Events

If the incoming Timecode suddenly skips to a new point in time, you can choose whether or not
to skip any events that would have been triggered in that missing time period.