IQOYA SERV/LINK user manual

two power cords. However, only one cord may be used.

IQOYA SERV/LINK starts as soon as it is connected to the mains.


Using only one power supply unit triggers the buzzer of the power supply units.

Connecting the second PSU stops the buzzer.

In case the second PSU is not used, stop the buzzer by pressing the red button labelled “R.A” on the back panel.
Note that this does not turn off the “Error” LED on the front panel and the PSU alarm on the LCD and WEB GUI.

24

5.5 Steps to follow to configure IQOYA SERV/LINK in “Program Distribution” mode of
use

Set the global parameters of your IQOYA SERV/LINK

If IQOYA is used for encoding:

● Adjust the parameters of the audio inputs

● Declare the programs

● Declare the IP services to be streamed over IP

Note that one program can be used by only one IP service.


If IQOYA is used for decoding:

● Adjust the parameters of the audio outputs

● Declare the IP services to be received from the network

● Declare the programs to be decoded from the received IP services

● Check the statuses and metrics on the output programs.

If IQOYA is used for transcoding:

● Declare the IP services to be received from the network

● Declare the programs to be decoded from the received IP services, and assign them to internal audio

buses.

Declare the input programs (select audio buses as the sources of these input programs)

Declare the IP services to be streamed over IP

Check the statuses and metrics on the output programs.