NARDA 8718B User Manual

Page 73

Advertising
background image

72

Operating the Meter

Many standards have

more than one tier,

i.e., IEEE C95.1-1999

establishes different

Maximum Permissi-

ble Exposure (MPE)

levels and averaging

times for Controlled

Environments and for

Uncontrolled Envi-

ronments.

N

ote

I E E E

C 9 5 . 1 - 1 9 9 9

C O N T R O L L E D

E N V I R

O K

S T N D S

F1

F2

F3

F4

5. Press F1 (OK) to continue using this standard as a

reference without change.

To change the standard or tier that the 8718B references...

6. Press F4 (STNDS). A new menu screen will

automatically appear that lists several major

international standards.

7. Press the number on the keypad that matches the

desired standard.

For standards with only a single tier...

8. A new screen will appear that lists the complete

standard number.

1

F C C ‘ 9 7

5

I R P A

2

I E E E ‘ 9 9

6

U S

D O D

3

A N S I ‘ 8 2

7

U K

4

A C G I H

8

N E X T

F1

F2

F3

F4

A N S I

C 9 5 . 1 - 1 9 8 2

O K

S T N D S

F 1

F 2

F 3

F 4