Cleaning the Field Lens

• By briefly depressing the “PHASE”-button, the shutter is

positioned to protect the mirror surface from damage as

far as possible.

• Before cleaning the field lens, switch the camera’s main

switch off and disconnect the camera from the power

supply!

• Remove the lens or the protective cap.

Do not touch the mirror surface!

• Pull the ground glass

photo

out of the holder by its

tongue

photo

using the special forceps.

• Using the special forceps, first lift the field lens

photo

upwards by its tongue

photo

then pull it out of its

holder.

• Clean the field lens with a dry, lint-free cloth.

• Make sure that the frame is completely clean.

• Using the special forceps, push the field lens as far as

it will go into the holder. A ball catch fixes the field lens

in the correct position.

• Check if the ground glass to be used and the ground

glass frame are completely clean.

• Using the special forceps, push the ground glass into

the holder as far as it will go. A ball catch fixes the

ground glass in the correct position.

• Check that the ground glass is locked in place.