2 exchanging the ground glass, Camera body – ARRI ARRIFLEX 235 User Manual

Page 40

Advertising
background image

40

40

7.2 Exchanging the Ground Glass

• By briefly depressing the “PHASE”-button in standby,

the shutter is positioned to protect the mirror surface

from damage as far as possible

photo

.

• Before exchanging the ground glass, switch the

camera’s main switch off and disconnect the camera

from the power supply!

• Remove the lens or the protective cap.

Do not touch the mirror surface!

• Using the included special forceps, pull the ground glass

photo

out of the holder by its tongue

photo

.

• Check that the ground glass to be inserted as well as

the ground glass frame are completely clean.

• With the special forceps, push the chosen ground glass

into the holder as far as it will go. The red marker

point must be on the left. A ball catch fixes the ground

glass exactly in the right position.

• Check that the ground glass is correctly locked in place.

Note:

Cleaning or exchanging the field lens, see

Chapter 13 Maintenance, Cleaning the Field Lens.

tongue

ground glass

Camera Body

Advertising