Check all settings on the connected monitor.

If the mechanical iris is closed more than necessary, the

IVS will compensate by increasing the gain and improve

the image brightness electronically. This creates additional

electronic noise. To avoid this, open the mechanical iris.

• To change the iris, turn the wheel with the iris symbol Õ.

10.3.3 Alignment of the image position

(X-, Y- and Rotation) and focus

The position of the image on the CCD-Chip and its focus

can vary slightly from camera to camera. The video

image on the monitor may appear not centered, rotated

or out of focus.

All settings can be made by using a 1,5 mm allen key,

which is delivered with the IVS.

Do not use force!

• Image position adjustments in x- and y- direction can

be made with the marked x- and y- screws

photo

.

• The screw, marked with Ò moves the video image on

the monitor horizontally. The screw, marked with Ó

vertically.

Ó

alignment

Note:

Due to design restrictions in size, the axis might

be not precisely in x- and y- direction

• Image rotation can be changed on the screw, marked

with the Ô-Symbol

photo

(page 80).

• Focus can be changes, using the screw, which is

marked with the F Symbol

photo

(page 80).

Ò

alignment