Command settings dialog box, Communic ation – IDEC High Performance Series User Manual

Page 129

Advertising
background image

WindO/I-NV2 User’s Manual

3-27

5 User Communication

3

Communic

ation

Command Settings Dialog Box

Specify the command details for user communication protocol.

Comment
Enter a comment for a command. The maximum number is 40 characters.

Command Type
Select the type of communication command from the following items.

TXD:

A command for data transmission from the MICRO/I to an external device.

Processing of transmission command is as follows.

Example: When Trigger Type in Trigger Condition is Rising-edge, Device is LM100 and

Completed Device is LM101
When the value of the Trigger Condition device LM100 changes to 1, data is transmitted
by user communication from the MICRO/I to the external device. When data transmission
is successfully completed, the value of the Completed Device LM101 changes to 1.

Transmission

data

Transmission

1

(31h)

2

(32h)

3

(33h)

4

(34h)

External device

MICRO/I

Value of LM100 when

Trigger Condition is

Rising-edge

1

0

Value of Completed Device

LM101

1

0

Transmission data

State in which user

communication is

not operating

State in which data can be

transmitted by user communication

State in which user

communication is

not operating

Complete

transmission

Start

transmission

Advertising