3 properties of word write command dialog box, General tab, Properties of word write command dialog box -12 – IDEC High Performance Series User Manual

Page 748: 2 word write command, Windo/i-nv2 user’s manual

Advertising
background image

2 Word Write Command

12-12

WindO/I-NV2 User’s Manual

2.3 Properties of Word Write Command Dialog Box

This section describes items and buttons in the Properties dialog box.

General Tab

Part Name
Enter a name for the part. The maximum number is 20 characters.

Action Mode
Select the action to perform when the trigger condition is satisfied from the following:

Set:

Writes a fixed value to the specified word device when the trigger condition is satisfied.

Move:

Writes the value in the source device to the destination word device when the trigger condition is

satisfied.

Momentary:

Writes the fixed ON Data value to the specified word device when the trigger condition is satisfied.
Writes the fixed OFF Data value to the specified word device when the trigger condition is no
longer satisfied.

State of condition

Data written

Write

Action

Write

Value

Value

Condition

Condition

Condition

Condition

Satisfied

Satisfied

Satisfied

Not satisfied

Not satisfied

Not satisfied

Satisfied

Satisfied

Satisfied

Not satisfied

Not satisfied

Not satisfied

State of condition

Data written

Write

Action

Write

Value in device

Value in device

Condition

Condition

Condition

Condition

Satisfied

Satisfied

Satisfied

Not satisfied

Not satisfied

Not satisfied

Satisfied

Satisfied

Satisfied

Not satisfied

Not satisfied

Not satisfied

State of condition

Data written

Write

Action

OFF Data

Write

ON Data

Write

OFF Data

Write

ON Data

Condition

Condition

Condition

Condition

Satisfied

Satisfied

Satisfied

Not satisfied

Not satisfied

Not satisfied

Satisfied

Satisfied

Satisfied

Not satisfied

Not satisfied

Not satisfied

Advertising
This manual is related to the following products: