Trigger condition tab – IDEC High Performance Series User Manual

Page 654

Advertising
background image

9 Numerical Display

10-142

WindO/I-NV2 User’s Manual

Trigger Condition Tab

The Trigger Condition tab is displayed in Advanced mode.

The Numerical Display is enabled while the condition is satisfied, and it is disabled while the condition is not satisfied.
Select the operation when the condition is not satisfied as Not display Numerical data or Not update Numerical
data
under While not satisfying the condition. For the HG2G-5F and the HG3G/4G, you can also select Not
show Numerical Display
.

Trigger Type
Selects the condition to enable the Numerical Display from the following.

Example: When Trigger Type is While ON, Device is LM 0, and While not satisfying the condition is Not

display Numerical data
While LM 0 is 0, the condition is not satisfied and the Numerical Display does not display the number.
While LM 0 is 1, the condition is satisfied and the Numerical Display displays the number.

LM0:

MICRO/I

0

LM0: 1

1234

Condition

Not

satisfied

Condition

Satisfied

Show

number

Hide

number

Data over does not operate for hidden Numerical Displays. Data over is reported if the minimum or
maximum is exceeded when the Numerical Display changes from hidden to displayed.

Always visible: The Numerical Display is always enabled.

Display

Data

99

100

101

102

103

104

105

Update

Update

Update

Update

Update

Update

Update

99

100

101

102

103

104

105